Air conditioning
Climate calculator
Calculate the minimum power that the air conditioner should have for your space.
Result for the room m x m x m: kw
Filtering

- Nominal heating capacity (kW): 11,14
- Nominal cooling capacity (kW): 10,55
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,4

- Nominal heating capacity (kW): 7,62
- Nominal cooling capacity (kW): 7,03
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,2

- Nominal heating capacity (kW): 5,57
- Nominal cooling capacity (kW): 5,28
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,3

- Nominal heating capacity (kW): 3,81
- Nominal cooling capacity (kW): 3,52
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4,1
- SEER coefficient: 6,6

- Nominal heating capacity (kW): 2,93
- Nominal cooling capacity (kW): 2,64
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C

- Nominal heating capacity (kW): 11,72
- Nominal cooling capacity (kW): 10,55
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,1

- Nominal heating capacity (kW): 18,17
- Nominal cooling capacity (kW): 15,24
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,1

- Nominal heating capacity (kW): 16,12
- Nominal cooling capacity (kW): 14,07
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,1

- Nominal heating capacity (kW): 7,62
- Nominal cooling capacity (kW): 7,03
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,2

- Nominal heating capacity (kW): 5,57
- Nominal cooling capacity (kW): 5,28
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,5

- Nominal heating capacity (kW): 3,81
- Nominal cooling capacity (kW): 3,52
- Područje rada prilikom grijanja: -20 °C ≤ T ≤ 24 °C
- Operating area during cooling: -15 °C ≤ T ≤ 50 °C
- SCOP coefficient: 4
- SEER coefficient: 6,3

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 15,5
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 15,5
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 10
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 10
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 10
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Ekspanzijska posuda (primarni krug) - volumen (L): 8
- Nominal capacity: 6,5
- Dimenzije uređaja (mm): 420 × 790 × 270
- Water supply temperature - heating (˚C): 25 °C ≤ T ≤ 65 °C
- Water outlet temperature - cooling (˚C): 5 °C ≤ T ≤ 25 °C

- Nominal heating capacity (kW): 15,9
- Nominal cooling capacity (kW): 14,9
- SCOP - starting temperature 35 ˚C: 4,62
- SCOP - starting temperature 55 ˚C: 3,41
- SEER - departure temperature 7 ˚C: 4,67
- SEER - starting temperature 18 ˚C: 6,71

- Nominal heating capacity (kW): 15,9
- Nominal cooling capacity (kW): 14,9
- SCOP - starting temperature 35 ˚C: 4,62
- SCOP - starting temperature 55 ˚C: 3,41
- SEER - departure temperature 7 ˚C: 4,67
- SEER - starting temperature 18 ˚C: 6,71

- Nominal heating capacity (kW): 14,5
- Nominal cooling capacity (kW): 13,5
- SCOP - starting temperature 35 ˚C: 4,72
- SCOP - starting temperature 55 ˚C: 3,47
- SEER - departure temperature 7 ˚C: 4,83
- SEER - starting temperature 18 ˚C: 6,85

- Nominal heating capacity (kW): 14,5
- Nominal cooling capacity (kW): 13,5
- SCOP - starting temperature 35 ˚C: 4,72
- SCOP - starting temperature 55 ˚C: 3,47
- SEER - departure temperature 7 ˚C: 4,83
- SEER - starting temperature 18 ˚C: 6,85